e-space
Manchester Metropolitan University's Research Repository

    2D and 3D PVA electrospun scaffold evaluation for ligament implant replacement: a mechanical testing, modelling and experimental biomechanics approach

    Roldan Ciudad, Elisa ORCID logoORCID: https://orcid.org/0000-0002-7793-7542, Reeves, Neil D ORCID logoORCID: https://orcid.org/0000-0001-9213-4580, Cooper, Glen ORCID logoORCID: https://orcid.org/0000-0002-9568-8973 and Andrews, Kirstie ORCID logoORCID: https://orcid.org/0000-0002-0860-0604 (2024) 2D and 3D PVA electrospun scaffold evaluation for ligament implant replacement: a mechanical testing, modelling and experimental biomechanics approach. Materialia, 33. 102042. ISSN 2589-1529

    [img] Accepted Version
    File will be available on: 24 February 2025.
    Available under License Creative Commons Attribution Non-commercial No Derivatives.

    Download (2MB)

    Abstract

    The gold standard to characterise anterior cruciate ligament (ACL) implants is through the evaluation of mechanical properties such as Young's modulus or ultimate tensile stress. Currently, no studies have been performed to relate the in-vivo hyper-elastic behaviour of the ACL with the design of tissue engineered ligaments. The aim of this work is to determine the most comparable 2D/3D polyvinyl alcohol (PVA) electrospun structure to the in-vivo mechanical behaviour of the natural ligament. Biomechanics of 12 young participants were captured while daily and high impact activities were performed. A musculoskeletal knee model and kinematic data were used to estimate the in-vivo ACL length and strain. The in-vivo ACL tensile forces were determined with a non-linear force/strain relationship. 2D scaffolds, 1 twisted filament scaffolds, 3 twisted filaments scaffolds and 3 twisted/braided filaments scaffolds were fabricated using electrospinning and characterised morphologically and mechanically using scanning electron microscopy and tensile testing respectively. Cyclic tensile and shear tests were performed in dry and wet conditions to crosslinked and non-crosslinked samples. The hyper-elastic behaviour of our PVA scaffolds was characterised with the Mooney Rivlin model and a non-linear string-based model, and both models compared with the in-vivo mechanical behaviour of the native ACL. Crosslinked 3 twisted/braided filaments scaffolds faithfully mimicked the morphology and the hyper-elastic behaviour of the natural ACL, showed a good resistance to shear loading and remained undegraded in phosphate-buffer saline solution. This study demonstrated, for the first time, that 3 twisted/braided filaments PVA electrospun scaffolds have an excellent potential for ACL replacements.

    Impact and Reach

    Statistics

    Activity Overview
    6 month trend
    3Downloads
    6 month trend
    70Hits

    Additional statistics for this dataset are available via IRStats2.

    Altmetric

    Repository staff only

    Edit record Edit record