    Validity of the Hawkin Dynamics wireless dual force platform system against a piezoelectric laboratory grade system for vertical countermovement jump variables

    Dos'Santos, Thomas ORCID logoORCID: https://orcid.org/0000-0003-2715-0116, Evans, Daniel T and Read, Dale B ORCID logoORCID: https://orcid.org/0000-0001-6367-0261 (2024) Validity of the Hawkin Dynamics wireless dual force platform system against a piezoelectric laboratory grade system for vertical countermovement jump variables. Journal of Strength and Conditioning Research, 38 (6). pp. 1144-1148. ISSN 1064-8011

    [img] Accepted Version
    File will be available on: 1 June 2025.
    Available under License In Copyright.

    Download (270kB)

    Abstract

    The aim of this study was to determine the criterion validity of the Hawkin Dynamics (HD) wireless dual force platform system for assessing vertical countermovement jump (CMJ) variables, compared with those derived from a Kistler piezoelectric laboratory grade force platform system. During a single testing session, HD force platforms were placed directly on top of 2 adjacent Kistler force platforms to simultaneously collect vertical ground reaction forces produced by 2 male recreational soccer players (age: 29.0 ± 2.8 years, height: 1.79 ± 0.01 m, mass: 85.6 ± 4.7 kg) that performed 25 vertical CMJs each. Sixteen vertical CMJ variables pertaining to jump height (JH), flight time (FT), time-to-take off (TTT), countermovement depth, body weight (BW), propulsive and braking mean, and peak powers, forces, and impulses were compared between systems. Fixed bias was observed for 6 of 16 variables (peak and mean braking power, mean propulsion force, TTT, FT, and BW), while proportional bias was present for 10 of 16 variables (peak and mean propulsive and braking force, TTT, FT, peak and mean braking power, mean propulsive power, and BW). For all variables regardless of fixed or proportional bias, percentage differences were ≤3.4% between force platform systems, with near perfect to perfect correlations (r or ρ = 0.977-1.000) observed for 15 of 16 variables. The HD dual wireless force platform system can be considered a valid alternative to a piezoelectric laboratory grade force platform system for the collection of vertical CMJ variables, particularly outcome (i.e., JH, reactive strength index modified) and strategy variables (countermovement depth).

    Impact and Reach

    Statistics

    Activity Overview
    6 month trend
    1Download
    6 month trend
    51Hits

    Additional statistics for this dataset are available via IRStats2.

    Altmetric

    Repository staff only

    Edit record Edit record