    Criterion validity and reliability of knee frontal plane projection angles measured using the technique application

    Atkins, Lee T, Van Bastian, Tyler, Eckert, Sterling D, Hofmann, Timothy R, Pierce, Emily L, Richards, Jim, Selfe, James ORCID logoORCID: https://orcid.org/0000-0001-9931-4998 and Callaghan, Michael ORCID logoORCID: https://orcid.org/0000-0003-3540-2838 (2022) Criterion validity and reliability of knee frontal plane projection angles measured using the technique application. Journal of Sport Rehabilitation, 31 (6). pp. 797-802. ISSN 1056-6716

    [img]
    Preview
    Accepted Version
    Available under License In Copyright.

    Download (715kB) | Preview

    Abstract

    Context: Abnormal knee frontal plane projection angles (FPPA) during movement have been associated with patellofemoral pain. As such, clinicians are interested in valid and reliable instruments suitable for broad-based clinical use that allow them to objectively measure such variables. Therefore, the purpose of the current study was to examine the criterion validity and reliability of knee FPPA measures obtained by clinicians using a free tablet application called Technique. Design: Validity/reliability study. Methods: To examine validity, the same raters measured 10, two-dimensional criterion reference angles at the first testing session. To examine reliability, the knee FPPA of 16 subjects was measured by 6 raters (3 physical therapists and 3 student physical therapists) on 2 separate occasions while performing a single-limb step-down task. Validity was investigated by calculating the 95% limits of agreement, mean absolute differences, and Bland–Altman plots. Reliability was examined by calculating intraclass correlation coefficients and the SE of measure. Results: For validity, the mean absolute difference between rater and criterion reference angle measures ranged from 0.20° to 0.90°. Ninety-five percent of expected errors between rater and criterion reference angle measures were 2.04° or less. For reliability, the intraclass correlation coefficient values for interrater and intrarater reliability were excellent ranging from .994 to .998 with SE of measure ranging from 0.44° to 0.84°. Conclusions: These findings indicate that knee FPPA measures obtained during a single-limb step-down task using the Technique tablet application are valid and reliable, and suitable for clinical use.

    Impact and Reach

    Statistics

    Activity Overview
    6 month trend
    311Downloads
    6 month trend
    259Hits

    Additional statistics for this dataset are available via IRStats2.

    Altmetric

    Repository staff only

    Edit record Edit record