e-space
Manchester Metropolitan University's Research Repository

Reproducibility of telomere length assessment: an international collaborative study.

Cooper, Rachel and Martin-Ruiz, CM and Baird, D and Roger, L and Boukamp, P and Krunic, D and Cawthon, R and Dokter, MM and van, der Harst P and Bekaert, S and de, Meyer T and Roos, G and Svenson, U and Codd, V and Samani, NJ and McGlynn, L and Shiels, PG and Pooley, KA and Dunning, AM and Cooper, R and Wong, A and Kingston, A and von, Zglinicki T (2014) Reproducibility of telomere length assessment: an international collaborative study. International Journal of Epidemiology, 44 (5). pp. 1673-1683. ISSN 0300-5771

[img]
Preview

Available under License Creative Commons Attribution.

Download (528kB) | Preview

Abstract

Background: Telomere length is a putative biomarker of ageing, morbidity and mortality. Its application is hampered by lack of widely applicable reference ranges and uncertainty regarding the present limits of measurement reproducibility within and between laboratories. Methods: We instigated an international collaborative study of telomere length assessment: 10 different laboratories, employing 3 different techniques [Southern blotting, single telomere length analysis (STELA) and real-time quantitative PCR (qPCR)] performed two rounds of fully blinded measurements on 10 human DNA samples per round to enable unbiased assessment of intra- and inter-batch variation between laboratories and techniques. Results: Absolute results from different laboratories differed widely and could thus not be compared directly, but rankings of relative telomere lengths were highly correlated (correlation coefficients of 0.63–0.99). Intra-technique correlations were similar for Southern blotting and qPCR and were stronger than inter-technique ones. However, inter-laboratory coefficients of variation (CVs) averaged about 10% for Southern blotting and STELA and more than 20% for qPCR. This difference was compensated for by a higher dynamic range for the qPCR method as shown by equal variance after z-scoring. Technical variation per laboratory, measured as median of intra- and inter-batch CVs, ranged from 1.4% to 9.5%, with differences between laboratories only marginally significant ( P  = 0.06). Gel-based and PCR-based techniques were not different in accuracy. Conclusions: Intra- and inter-laboratory technical variation severely limits the usefulness of data pooling and excludes sharing of reference ranges between laboratories. We propose to establish a common set of physical telomere length standards to improve comparability of telomere length estimates between laboratories.

Impact and Reach

Statistics

Downloads
Activity Overview
19Downloads
40Hits

Additional statistics for this dataset are available via IRStats2.

Altmetric

Actions (login required)

Edit Item Edit Item